Default parts can be added to characteristics.
Field | Description |
---|---|
Characteristic |
Displays the name of the selected characteristic. |
Part* |
Zoom to select the part to add to the characteristic. The user can filter the displayed parts by Part - All or by Parts - Quality Assured. |
Type* |
Click the drop down button and select the type of characteristic, such as Variable, Attribute, or Checklist. |
Severity* |
Click the drop down button and select the severity of the characteristic. This field defaults from information entered in the selected characteristic. |
Descriptor |
Enter an additional descriptive term. This field is only displayed if Attribute is selected as the Type. |
Nominal* |
Enter a nominal value and select the unit of measurement. |
Tolerance (+ and -)* |
Click the up and down arrows to specify the range within which the variable must fall in order to pass the inspection. This field is only applicable if Variable is selected as the Type. |
Apply to First Inspection Only |
Check this check box to apply the characteristic to the first inspection only. This field is used in Inspection Management. |
Sampling Plan |
Click the drop down button and select the sampling plan to be used for the part. The sampling plan indicates the number of parts from each lot that are to be inspected (sample size or series of sample sizes). This field is used in Inspection Management. |
AQL |
Click the drop down button and select the acceptable quality limit for the lot, such as .4 or 10.0. The AQL is a quality measurement for maximum numbers of defects that a manufacturer can tolerate. This field is used in Inspection Management. |
Document Number |
Zoom to select a document from the Document Management system. If Document Management is not installed, then enter a reference number for an external document. Forms Designer can be used to configure this field to link to an external document system. |
Document Revision |
Enter the referenced document's revision number. |
Reference Number |
Enter the referenced document's reference number. |
Equipment |
Enter the equipment used for the characteristic. |
Description |
Enter a description of the characteristic. |
NOTE: Parts that are tied to characteristics cannot be deleted from master setup. To delete the part from master setup, the part must first be removed from the Characteristic record.
See Also
|